Menu
Back
  1. Products
  2. Automation technology - Sensors and actuators
  3. M12-A
  4. M12 Male panel mount connector, Contacts: 12, unshielded, single wires, IP68, M12x1.0, front fastened
Part no.: 76 1031 1011 00012-0200

M12 Male panel mount connector, Contacts: 12, unshielded, single wires, IP68, M12x1.0, front fastened

M12-A, series 763, Automation Technology - Sensors and Actuators
Available numbers of contacts
Compare product
Downloads
General features
Moreless
Part no. 76 1031 1011 00012-0200
Connector design Male panel mount connector
Version Connector pin straight
Connector locking system screw
Termination single wires
Degree of protection IP68
Cross-sectional area 0.50 mm² / AWG 26
Temperature range from/to -40 °C / 85 °C
Mechanical operation > 100 Mating cycles
Weight (g) 16.20
Customs tariff number 85369010
Country of Origin DE
Rated voltage 30 V
Rated impulse voltage 800 V
Rated current 1.5 A
Insulation resistance > 108 Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance unshielded
Voltage 500 V DC
Housing material CuZn (Brass nickel plated)
Contact body material PA
Contact material CuZn (brass)
Contact plating Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number e7ba442e-95f7-41a2-a671-2dbd717416b6
Security notices
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
  4. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  5. The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
  6. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  7. The plug connector is not suitable for mains voltages Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
  8. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
  9. The protection class specification applies on condition that the four mounting holes are made as blind holes.
M12-A