Menu
Back
  1. Products
  2. Automation technology - Sensors and actuators
  3. M12-A
  4. M12 Adapter, 2.5-4.0 mm, shielded, solder, IP40
Part no.: 09 5247 00 12

M12 Adapter, 2.5-4.0 mm, shielded, solder, IP40

M12-A, series 713, Automation Technology - Sensors and Actuators
Compare product
Downloads
General features
Moreless
Part no. 09 5247 00 12
Connector design Adapter
Type standard DIN EN 61076-2-101
Termination solder
Degree of protection IP40
Cross-sectional area 0.25 mm² / AWG 24
Cable outlet 2.5-4.0 mm
Temperature range from/to -25 °C / 70 °C
Mechanical operation > 100 Mating cycles
Weight (g) 61.15
Customs tariff number 85369010
Country of Origin DE
Rated voltage 60 V
Rated impulse voltage 800 V
Rated current 1.5 A
Pollution degree 1
Overvoltage category II
Insulating material group III
EMC compliance shielded
Shield connection Shield on the housing
Contact body material PA
Contact material CuSn (bronze)
Contact plating Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number 7199ac1c-1f07-4e1c-a720-bab9285396a9
eCl@ss 11.1 27-44-01-09
ETIM 9.0 EC003569
RoHS Directive 2011/65/EU (EN 50581:2012)
Security notices
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  4. The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
  5. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  6. The plug connector is not suitable for mains voltages Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
  7. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
Downloads
Data sheet
Data sheet 09 5247 00 12
PDF
REACH
09 5247 00 12
PDF
RoHS
09 5247 00 12
PDF
China RoHS
09 5247 00 12
PDF
Declaration of conformity, RoHS Directive
Declaration of conformity
RoHS Directive
PDF
UKCA declaration of conformity, UK-RoHS
UKCA declaration of conformity
UK-RoHS
PDF
CAD files
Select required format
09 5247 00 12