Part no.: 99 9211 050 04

Snap-In Male panel mount connector, Contacts: 4, unshielded, solder, IP67, UL

Snap-In IP67, series 620, Subminiature Connectors
Available numbers of contacts
Compare product
Downloads
General features
Moreless
Part no. 99 9211 050 04
Connector design Male panel mount connector
Version Connector pin straight
Connector locking system snap-in
Termination solder
Degree of protection IP67
Cross-sectional area max. 0.25 mm² / AWG 24
Temperature range from/to -25 °C / 85 °C
Mechanical operation > 500 Mating cycles
Weight (g) 2.01
Customs tariff number 85369010
Country of Origin DE
Rated voltage 125 V
Rated impulse voltage 1500 V
Rated current 2.5 A
Insulation resistance ≥ 1010 Ω
Pollution degree 2
Overvoltage category II
Insulating material group II
EMC compliance unshielded
Housing material PA
Contact body material PA (UL94 HB) red
Contact material CuZn (brass)
Contact plating Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number fd0da4e3-9a9b-466a-93a4-58da03a2265e
eCl@ss 11.1 27-44-01-02
ETIM 9.0 EC002635
Security notices
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  4. The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
  5. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  6. The plug connector is not suitable for mains voltages Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".